IPEC (Ideh-Pouyan Energy Co.) is a private company, specialized in engineering and services of different types of pipelines. According to the team’s high level of expertise in both onshore and offshore pipelines, IPEC is always interested to carry out projects that challenge the engineering society of oil and gas industry. Our capability spans all types of pipeline services such as basic design, detailed design and precommissioning. By employing the most capable and experienced engineers and industry leading processes, we aim to serve our clients with state-of-the-art services.
IPEC employs highly qualified individuals from a variety of engineering disciplines and has strong commitment to training and continuous personal development of its team.
Beside from gathering a spectacular team, IPEC also has a close contact with local and international partners who have made IPEC gain reputation among most of the local project owners.
select category
Design Pressure: 400 bar
Interior Equipment and Instruments:
Communication Interface:
Operating Temperature: 0°C to +50°C
Storage Temperature: -10°C to +70°C
Input Types:
Recording Interval: 1 sample per channel per 0.1 s to 24 hours
Memory Capacity: 1.5 GB
Pressure and Temperature Chart Recorder
Model: INDUMART Sentinel Series 90
Number of Pens:
Operating Temperature: 0°C to +55°C
Accuracy:
Pressure Transmitter: 4 to 20 mA
Temperature Transmitter: Platinum RTD
Time Range: 24 hours
Radial Span: 0% to 100%
Time Division: 15 minutes
Radial Division: 2% of full scale
Model: KROHNE – IFM 4100 F
Size: 16 inch
Inlet: 3 x 8’’
Outlet: 3 x 8’’
Full-Scale Flow Rate Range: 120 to 5000 m3/hr
Ambient Temperature:
Accuracy: ±0.4%
Brand: Arkon
Model: MAGX2
Size and Port: DN 20
Range: 0.57 m³/hr to 11.31 m³/hr
Accuracy: ±0.2%
Maximum Pressure: 300 psi
Ambient Temperature: -20 °C to +60 °C
Medium Temperature: Maximum: +70 °C
Measurable Media: Conductive Fluids (= 5 µS/cm)
Material:
Brand: Arkon
Model: MAGX2
Size: DN 50
Range: 3.6 m³/hr to 70.56 m³/hr
Accuracy: ± 0.2%
Maximum Pressure: 300 psi
Ambient Temperature: -20 °C to +60 °C
Medium Temperature: Maximum: +70 °C
Measurable Media: Conductive Fluids (= 5 µS/cm)
Material:
Brand: Arkon
Model: MAGX2
Size: DN 150
Range: 32.4 m³/hr to 637.2 m³/hr
Accuracy: ± 0.2%
Maximum Pressure: 300 psi
Ambient Temperature: -20 °C to +60 °C
Medium Temperature: Maximum: +70 °C
Measurable Media: Conductive Fluids (= 5 µS/cm)
Material:
Model: KF 500
Size: DN 50
Flow Range: 4m3/hr to 40 m3/hr
Pulse/Lit: 100
Resolution: <0.01L
Flow Medium: liquids without particles
Pressure Rating: 25 bar
Pressure Loss: 0.4 bar
Inlet/Outlet Size: 2”
Fluid Temperature: -20°C to +100°C
Ambient Temperature: -25°C to 55°C
Ambient Humidity: = 80% RH
Viscosity: ≤ 5 mPa.s
Model: 46547-1005-2F66
Size: DN 5
Flow Range: 0.1 L/min to 2.5 L/min
Pulse/Lit: 18500
Resolution: 1/18500 L
Pressure Rating: 25 bar
End Connection: G 3/8”
Temperature Range: -20°C to +100°C
Model: KF 500
Size: DN 6
Flow Range: 100 L/hr to 600 L/hr
Pulse/Lit: ˜ 2500
Resolution: < 1/2500 L
Pressure Rating: 63 bar
Inlet/ Outlet Size: G 3/8”
Temperature Range: -20°C to +100°C
Ambient Temperature: -25°C to 55°C
Ambient Humidity: = 80% RH (non-condensing)
Viscosity: ≤ 5 mPa.s
Model: 46500-164-4F44
Size: DN 8
Flow Range: 1 L/min to 15 L/min
Pulse/Lit: 2200
Resolution: 1/2200 L
Pressure Rating: 25 bar
End Connection: G 3/8”
Temperature Range: -20°C to +100°C
Accuracy: ±3% of reading
Model: 46500-164-4F44
Size: DN 8
Flow Range: 1 L/min to 15 L/min
Pulse/Lit: 2200
Resolution: 1/2200 L
Pressure Rating: 25 bar
End Connection: G 3/8”
Temperature Range: -20°C to +100°C
Accuracy: ±3% of reading
Model: 46510-164-2F66
Size: DN 6
Flow Range: 0.5 L/min to 5 L/min
Pulse/Lit: 6900
Resolution: 1/6900 L
Pressure Rating: 25 bar
End Connection: G 3/8”
Temperature Range: -20°C to +100°C
Transmitter Type: Piezoresistive
Output: 4-20 mA
Accuracy: Min 1%
Connection Size: G ¼
Protection Level: IP65
Sensor Type: PT-100
Accuracy: 0.1 °C
Range: 0~100 °C
Cable Length: 30 meter (Zero Resistance Cable)
Type of Connection: 3-Wire Connection
Model: Indumart, DWT2700
Type: Dual range hydraulic deadweight tester
Pressure Range:
Resolution:
Accuracy: 0.015%
Dial Size: 100 mm
Case Material: Stainless Steel
Accuracy: 1%
Connection Size: ½ NPT
ROSEN ITX: 806 EX 30, 31, 32, 59, 84
ROSEN ITX: 504
ROSEN ITX: 251
Range: 2 – 7 m
Pressure resist: 200 bar
Weight: 0,258 – 10 kg
Battery life: 220 – 500 hr
TDW: CD42 T2
Range: 7,5 m
Pressure resist: 170 bar
Weight: 1,5 kg
Battery life: 500 hr
ROSEN: EPD II V 4.0 536, 537, 538
WeightL: 3,8 + 2,5 kg
Battery life: 200 hr
TDW: CD42- R
Weight: 3,5 + 2,7 kg
Battery life: 180 hr
Rosemount
Type: sensor of pressure
Range: 0 – 200 bar
Accuracy: 0,05 – 0,1 %
DataCon
Type: sensor of overpressure (abs.)
Range: (-1) to 600 bar
Accuracy: 0,1 %
DataCon
Type: pressure/temperature logger
Range: (-1) to 800 bar
Accuracy (pressure): 0,05 %
Resolution (temperature): 0,1 °C
Extra: developed specially for CEPS pressure testing,
independent display unit
Strain pressure gauge: Ø 160 mm
Range: (-1) to 400 bar
Accuracy: 0,6 – 1 %
Testo : 512
Type: differential
Range: 0 – 2 bar
Accuracy: ± 0,5 % of measured value
Testo: 511
Type: absolute
Range: 0,3 – 1,2 bar
Accuracy: ± 3 hPa
GE Sensing, type: 3113-1
Type: piston, deadweight tester
Range: 10 – 350 bar
Accuracy: 0,015 % of reading
Testo: 925
Range: (-50) to (+1000) °C
Accuracy: ± 0,5 °C
Testo: 720
Range: (-100) to (+800) °C
Accuracy: ± 0,2 °C
Comet
Type: logger
Range: (-90) to (+260) °C
Accuracy: ± 0,4 °C / ± 0,5 % MV
Testo: 625
Range: (-10) to (+60) °C, 0 – 100 % RH
Accuracy: ± 0,5 °C, ± 2,5 % RH
(for the range 5 – 95 % RH)
Vaisala: DM 70
Type: logger
Range: (dew point) 0 to (-60) °C
Range: (gas temperature) (-40) to 200 °C
Comet
Type: logger
Range: (-30) to (+105) °C, 0 – 100 % RH
Accuracy: ± 0,4 °C, ± 2,5 % RH (for the range 5 – 95 % RH)
Extra: recording temperatures and humidity during
the drying pipelines
Sewerin: Ex-Tec Od 4/Gm 4
Type: oxygen and flammable gasses detector
Range: 0 – 25 % vol.
Method: electrochemical
Gaztox
Type: oxygen detector
Range: 0 – 30 % vol.
Resolution: 0,1 %
Sewerin: EX-TEC PM 300
Type: methane detector
Range: 0 – 4,40 % vol. (reaction heat)
0 – 100 % vol. (thermal conductivity)
JTO GD 110
Type: methane detector
Range: 0 – 2 % vol.
Oxygen content: in gas 21 % (± 2 %)
Krautkrämer Branson DM 3, DM 4,
Krautkrämer MIC 10
Type: thickness and hardness meter
Range: 0,6 – 500 mm (DM3)
2 – 25 mm (DM4)
20 – 1740 HV (MIC 10)
Krohne, Badger, Sigma Flow, Comac Cal
Type: magnetic induction flowmeter
Range: 0 – 530 m³/hr
Accuracy: 0,5 %
Extra: installed
Elster:, Prema-H. Meinecke
Type: mechanical flowmeter
Range: 0 – 40 m³/hr
PRYMAYER Hykron
Battery: 9 V
Range: 30 – 5000 Hz
Extra: zero internal noise
EZiZCAT: i500
Passive modes: power, radio
Active modes: 8 kHz, 33 kHz
Auto mode: combined power and radio
Weight: 2,7 kg